MiS210/MiS250 Enhanced Motion Safety, Decentralised Flexibility, Ethernet Connectivity

January 12, 2022

Relying on a centralised safety PLC can mean additional cost through complexity of the wiring and safety software. Alternatively, electromechanical safety devices typically mean lower throughput, longer machine stoppages and extra time required for set-up and maintenance. The new MiS210/MiS250 safety option for Unidrive/Digitax extends the built-in STO with motion safety capability and enables decentralised flexibility with the option of safety over ethernet connectivity.

Supported motion safety functions 
  • Safe Stop 1 (SS1)
  • Safe Stop 2 (SS2)
  • Safe Operating Stop (SOS)
  • Safe Brake Control (SBC)
  • Safe Direction (SDI)
  • Safely Limited Speed (SLS)
  • Safely Limited Acceleration (SLA)
  • Safely Limited Position (SLP)
  • Safe Speed Monitor (SSM)
  • Safe Emergency Stop (SES)
  • Safe Two-Handed Control
Safety over ethernet 
  • Supports CIP Safety over EtherNet/IP
  • Supports Safety over EtherCAT (FSoE)
Safety certifications 

MiS210 and MiS250 have been independently assessed by TUV Rheinland to meet the following standards:

  • IEC 61508 SIL3
  • IEC 62061
  • ISO 13849-1 PLe
  • IEC 61800-5-2
  • European Machinery Directive 2006/42/EC 
Fast and simple set-up

The MiS210/MiS250 customer fit option module simply clicks into place, with no screws or other mounting requirements.

Once fitted, the safety functions are seamlessly incorporated into the drive’s feature set.

  • Easy configuration with Connect, the free drive management PC tool for CT drives
  • Simple parametric interface
  • No code to write nor new programming language to learn
Decentralised motion safety flexibility

MiS210/MiS250 enables motion safety decentralisation in combination with the appropriate encoder. This can remove the need for a central safety PLC and reduce the number of sensors necessary to achieve the required SIL/PL level.

Benefits of integrated safety include:

  • Reduced wiring and costs
  • Ease and speed of commissioning
  • Speed of actuation thanks to close coupling of safety function and drive
  • Reduced footprint and cabinet size
  • Scalable SIL through choice of encoders – up to SIL 3 with a single, motor-mounted encoder
  • SISTEMA library integration
  • Incrementally add safety functionality

 

Learn more about the MiS210.MiS250, click here 

 

Related Articles



Editor’s Pick: Featured Article

Weidmüller’s u-control 2000: The Automation Controller

Weidmüller’s u-control 2000: The Automation Controller

Weidmüller’s scalable engineering software, u-control 2000, adapts individually to your requirements. And, the u-control is powerful, compact and fully compatible with Weidmüller’s I/O system u-remote. This article looks at what makes u-control the heart of your automation.

Programmable logic controllers (PLCs) are one of the main components of any automated system. A typical control system has inputs, outputs, controllers (i.e., PLCs), and some type of human interaction with the system, a human machine interface (HMI), for example.

Read More



Latest Articles

  • Applications of Physical AI in Canadian Sectors

    June 23, 2026 Physical AI — the convergence of artificial intelligence with robotics and autonomous motion systems — is reshaping how Canadian industries operate. Across sectors from healthcare to mining, AI-enabled machines are performing tasks that were once entirely dependent on human intervention. But deploying Physical AI effectively requires more than sophisticated algorithms: it demands… Read More…

  • Case Study: Optimizing Harmonic Mitigation in Wastewater Treatment

    June 22, 2026 Segment and Application In a municipality, wastewater treatment plants typically stand out as the main consumers of electricity. The operational processes exhibit significant load variations throughout a 24-hour cycle, necessitating the use of AC drives to regulate pumps, blowers, and other motorized equipment in response to fluctuating demand. In one wastewater treatment… Read More…